There are several alternatives for consideration to provide sanitary sewerage for municipal services.
While gravity sanitary sewers may be the preferred solution, flat terrain, shallow groundwater or rock can increase construction cost prohibitively. Typically gravity sewers can extend (at 0.4% slope) for only 2,000 feet in flat terrain (8' drop) before a lift station is required. If houses have basements or groundwater/rock are issues, these problems can be exacerbated. Vacuum sewers can extend as far as 5,000 feet in all directions at 0.2% slope and have many cost-effective uses and a good 'tool' for use by municipalities and engineers. Flatter slopes to the vacuum lines and shallower construction provide definite advantages over traditional construction. This OnDemand Webinar will identify basics of vacuum sewers, locations for use, design issues, and use case histories as examples of the use of vacuum sewers. Learning Objectives: •You will be able to describe the basic process of vacuum sewers. •You will be able to discuss the basic design concept. •You will be able to identify equipment manufacturers. •You will be able to review how to objectively evaluate vacuum system design.
Add to Wishlist
More Program Information
Why Lorman?
Over 37 years and 1.4 million customers worth of experience providing continuing education. Our passion is providing you world-class training to help you succeed in business and as a professional.
Agenda
Use of Vacuum Sewers
- Where to Use - Flat Terrain; Rocky Subsurface; High Groundwater
- How to Use - Central Vacuum Pumping Station; Radiating Sewers From Single Central Source; Sawtooth Design at 0.2% Slope
Basic Design Concept
- Vacuum Station
- 18'20' Maximum Lift Allowed; Altitude of Site Critical to Consider
- Central Location Equal Lift Available in All Directions
- Major Equipment Components Vacuum Pumps, Vacuum Tank, Discharge Pump
- Operation/Maintenance Considerations
- Vacuum Sewers
- 0.2% Slope Minimum (Steeper Slope Ok); Minimum/Maximum Lifts Depending on Sewer Size; Gravity Flow (Vacuum Conditions) Between Lifts
- Minimum Length per Lift Generally 3550'
- Operation/Maintenance Considerations
- Proximity to Potable Water Piping
- Valve Pits
Equipment Manufacturers
- Provide Package Systems - House Connection Valves Are the Key
- USA - AirVac, Inc., Indiana
- Worldwide -
- Flovac Germany
- RoeVac Germany
Case Studies
- Albuquerque North/South Valleys
- Overall Service 11 Stations, 20 Miles of Sewers; 27,000 Persons Served
- Evolution of Vac Station Design Learning Process Through Operations
- In Service for Over 15 Years
- Other Locations
Add to Wishlist
More Program Information
Why Lorman?
Over 37 years and 1.4 million customers worth of experience providing continuing education. Our passion is providing you world-class training to help you succeed in business and as a professional.
Credits
OnDemand Course
This course was last revised on November 29, 2012.
Call 1-866-352-9540 for further credit information.
This program does NOT qualify, nor meet the National Standard for NASBA accreditation.
Add to Wishlist
More Program Information
Why Lorman?
Over 37 years and 1.4 million customers worth of experience providing continuing education. Our passion is providing you world-class training to help you succeed in business and as a professional.
Faculty
Robert (Bob) J. Paulette, , PE
Wilson & Company, Inc., Engineers & Architects
Robert J. Paulette, PE
- Engineer with Wilson & Company, Inc. and previous operations manager
- Chairman, NMIC of RMWEA/RMSAWWA
- Has written numerous papers on water/wastewater engineering throughout the world
- Articles previously published, “Vacuum Sewers – Engineered Solutions for a Multitude of Problems”, WEFTEC 06 Dallas TX, October 2006, and “Vacuum Sewers May be the Cost-Effective Solution for You”, Texas ASCE Conference, Amarillo, TX, September 2011
- M.S. degree in civil/environmental engineering, University of Iowa; B.S.C.E. degree, Kansas University
Add to Wishlist
More Program Information
Why Lorman?
Over 37 years and 1.4 million customers worth of experience providing continuing education. Our passion is providing you world-class training to help you succeed in business and as a professional.
All of your training, right here at Lorman.
Pay once and get a full year of unlimited training in any format, any time!
- OnDemand Courses
- Live Webinars
- MP3 Downloads
- Course Manuals
- Executive Reports
- White Papers and Articles
Additional benefits include:
- State Specific Credit Tracker
- All-Access Pass Course Concierge
Questions? Call 877-296-2169 to speak with a real person.
Access to all training products for one year
$699/year
Unlimited Lorman Training
With the All-Access Pass there is no guessing what you will need for your yearly training budget. $699 will cover all of your training needs for an entire year!
Easy Registrations
Once you purchase your All-Access Pass you will never be any further than one-click away from attending any Lorman training course.
Invest in Yourself
You haven't gotten to where you are professionally by luck alone; it's taken a lot of hard work and training. Invest in yourself with the All-Access Pass.